| Maximum
Sampling Rate |
30
Millions Samples per second |
| Minimum Sampling
Rate |
3000 Samples per
second |
| Maximum
sample lengths of 21 seconds with 64K buffer @ 3000sps |
| Buffer Size |
Selectable 2K,
4K, 8K, 16K, 32K & 64K 12bit data points |
Analogue |
| Analogue channels
input Ranges |
+-1.0V and +-10V
(+-100V with X10 probes) |
| Analogue input
modes |
Software
selectable AC or DC for analog inputs. |
| Analogue input
bandwidth |
~15MHz |
| Analogue input
impedance |
~ 1Mohms // 22pf |
| Maximum allowable
voltage at inpu;)t |
+-20V |
| Analogue input
resolution |
12-bit resolving
to less than 500uV per bit |
Digital |
| Digital channels
input |
Approximately
<0.5V for logic 0 and >2V for logic 1 |
| Digital input
mode |
DC only |
| Digital input
bandwidth |
~ 100MHz |
| Digital input
impedance |
~ 20K // 22pf |
| Maximum allowable
voltage range at input |
more than -2V and
less than +10V |
| Digital input
resolution |
1-bit.
Logic Low or High |
Trigger |
| Trigger modes |
Instant or
Digitally Triggered (with filter option) with +/- slopes |
| Trigger
source |
Channel
A, B, C or D |
| Pretrigger
options |
OFF, 10 or 100
sample points |
Display |
| Display grid |
25mV/div to 2.5V/div (or 25V/div with X10 probe) |
Input |
| Input connectors |
All standard BNC |
| Stability |
(@ 20 oC)
Zero reading: +- 4 bits, Noise: ~ +- 2 bits at 2Msps (with inputs grounded) |
|
| Type |
FFT (Fast Fourier
Transform) |
| Range |
0 to 15 MHz |
|
| Frequency Range |
5Hz to 500KHz
settable to 1 percent. Accuracy to within 3% |
| Built-in signal types |
Sine, Triangular,
Saw, Square wave |
| Built-in signal modes |
Normal or Sweep |
|
Sweep Ratios of
X2, X5 X10 and X20 |
| Sweep start freq. |
7.5,15,75,150,750,1500,7500,15000,75000,150000
Hz |
|
Custom waves at
selectable 3K, 30K, 300K, 3M & 30M Hz rates |
|
Custom wave
loaded via simple text file, raw data or Excel CSV file |
|
Custom value of
4095 = 2V & 0 = 0V (12bits resolution) |
| Signal Amplitude |
Built-in
waveforms 0-1V and 0-2V pp |
| Output impedance |
200 Ohms |
|
| Count Modes |
Frequency or
Counter |
| Minimum signal pulse width |
~ 10nS |
| Frequency count range |
1 to 100,000,000
Hz 9-digit display with 1Hz resolution |
| Frequency accuracy |
~ 0.01% +- 1
digit, stability +-100ppm/oC |
| Frequency source
inputs |
Analogue channels
A or B or digital channels C or D |
| Counter range |
0 to
1,073,741,823 counts |
| Counter source |
Analogue channels
A or B or digital channels C or D or 1MHz reference |
| Counter control |
Ch C (+ edge
start & - edge stop), D (-edge start +edge stop) or Manual |
| Pulse width
measurement (+ or -) |
1 us to 1000
seconds using internal 1MHz reference |
Most counter functions are also available in Generator Mode |
|
SCOPE, GENERATOR, SCOPE & GENERATOR, FFT, COUNTER |